RM2 Millennium Rack Mount Controller

Millennium-Rack-Mount-Controller-210x210

The RM2 Millennium is a 2-channel rack mount controller designed to offer you control and versatility. The RM2 has the flexibility to allow you to build a monitoring system to suit your installation requirements by combining any two of Net Safety’s flame detectors, toxic gas sensors or combustible gas sensors. Reduce costs and safeguard your installation against a variety of potential hazards or cover multiple zones with a single monitoring device.

The RM2’s independent channels eliminate the limitation of monitoring only flame or only gas by adding a new level of flexibility — and activity on one channel does not affect the other channel so a variety of tasks and activities can be performed without initiating false alarms. Setup, operate, monitor and maintain the RM2 using the Front Panel Push button, or connect a PC or a PDA via the serial communications port. The RM2 software allows users to program numerous options to configure the RM2 to exactly suit your needs – in the field and on demand! Operation and maintenance are simple without compromising safety or reliability. Specifically designed with end-user input, the RM2 shows you what you need to know quickly and easily. Each channel has its own clearly visible display with helpful prompts to guide you through setup and maintenance tasks.

Bright LEDs visually indicate warnings and alerts for each input channel and the RM2 circuitry. The Event Logging feature securely stores in protected RAM up to 1000 events automatically listing the date, time, channel, detector type and the associated alarm, fault or calibration event. Highly useful information for developing maintenance schedules or performing troubleshooting and sequence of events analysis.

  • RS-232 Serial Communications Port – Connect a PC or PDA
  • Channel Specific, Jumper Selectable Analog Output-Isolated/Non-Isolated
  • Pluggable Terminals
  • Protected Memory
  • Conformal Coated Circuit Board
  • Internal System Electronic Watchdog Timer
  • Rails to Easily Slide into Cages
  • Calibration/Reset Button
  • 4-Character Scrolling Display
  • Common System LEDs Indicate System and Fault Status
  • 5 SPDT Relays (2 Per Channel/1 Common Fault) Jumper Selectable as Normally Open or Closed
  • Relay Set Points (System Fault, Gas-High/Low, Fire-High/Low)
  • Current Output And Power Terminals
  • „„Calibration/Reset Button Programming, Clearing Alarms or Calibrations
  • High Intensity LEDs Indicate Fault and Alarm
    • RS-232 Serial COM Port Connect a Laptop or PDA for Setup and Event Logging
    • Five Jumper Selectable Relays Normally Open or Closed
  • Relay Set Points High/Low = Gas – Fire/Fault = Flame
  • Two 4–20 mA Analog Outputs for Gas and Flame Detectors
  • Four Character Scrolling Display – Visible in all Lighting Conditions.
  • Available Menu Languages:
    • English
    • Spanish
    • French

RM2 Rack Mount Controller – Dual Channel [Flame & Gas Detection]

P/N: RM2-ARD-XX
Operating Voltage Range: 10.5 to 32 Vdc
Power Consumption (at 24 Vdc): Nominal 150 mA (1.8 W / 3.0 W ) de-energized / energized maximum 290 mA / 3.48 W
Power Consumption (at 12 Vdc): Nominal 80 mA / 130 mA (1.92 W / 3.12 W) de-energized / energized maximum 160 mA / 3.84 W
Temperature Range: -40 °C to +80 °C (-40 °F to +176 °F)
Humidity Range: 0 to 100 % RH, non-condensing
Chassis Material: 16 gauge steel / powder coated
Weight: 2.1 Kg / 4.5 lb (Stainless Steel option 3.4 Kg / 7.5 lb)
Outputs: 4 to 20 mA – Into a maximum loop impedance of 800 Ohms at 32 Vdc or 150 Ohms at 10.5 Vdc, Isolated or non-isolated loop supply; Form C contacts rated 5 Amps at 30 Vdc / 250 Vac. Selectable energized/de-energized latching/non-latching, N.O. or N.C. Fault relay fixed as energized, non-latching; RS-485 RTU Modbus protocol
Warranty: 2 Year Warranty on Electronics